E1 and datacom tester

E1 and datacom tester

(1). G.703 Test and Jitter Test
(2). Applications for E1
(3). Applications for Datacom
(4). Applications for Co-directional 64Kbit/s

Description

As a professional manufacturer and supplier of sat-1cj e1 and datacom tester with jitter for sale, we warmly welcome you to wholesale the high quality and reasonable price equipment for sale from our factory.


SAT-1CJ E1 and Datacom Tester with Jitter

Key Features

(1). 5 inch LCD with backlight, the largest screen in the industry

(2). Handheld, rugged design, easy to operation

(3). Particular history and real-time LED indicator design, find troubles more 

       clearly.

(4). Smart auto configuration feature

(5). Alarm and Histogram analysis for troubleshooting

(6). Multi-task operation at the same time

(7). Store 99 test results and 7 test configurations, with power-off memory

(8). Large capacity battery support 6 hours work

(9). Automatically power on/off testing by programmable timer

(10). Powerful PC software supports download results to PC, data analysis, report 

        generation, printing, etc.

(11). Software updating

(12). G.703 Test and Jitter Test

 

Applications for E1

(1). Service-interrupted error testing

(2). On-line service error testing

(3). Framed and unframed signals generation and reception

(4). 2Mbit/s unframed error performance testing

(5). 2Mbit/s framed N×64Kbit/s channel error testing

(6). Bit error, coding error, frame error, CRC error and E-bit error testing

(7). Signal loss alarm, AIS alarm, framed remote alarm, multi-framed remote alarm, 

      out-of-frame and pattern loss alarm

(8).  Frequency offset transmitting

(9). Voice channel signal level and frequency testing

(10). Pattern slip testing

(11). Clock slip testing

(12). Pass through testing

(13). Audio frequency testing

(14). Loop delay test

(15). Automatic protection switching time testing (APS)

(16). Voice monitoring

(17). Send clock offset

(18). Two line of 2MBit/s testing, two-way monitoring

(19). G.703 analysis

(20). Jitter test (O.171, O.172)

(21). Signal state display, Voice channel content display, Voice channel 

         busy / idle indication.

(22). Alarm and error histogram analysis

(23).  Time slot content analysis, drop and insert signal on each time slot

(24).  Framed content analysis

(25).  G. 821/G. 826/M. 2100 performance analysis

(26).  Multi errors and alarms inserting

(27).  Three input modes (terminating, bridging and monitoring)

(28).  Provides two clock options (internal and picking-up);


Applications for Datacom

(1). Includes V.24/V.28/RS232, V.35, V.36/RS-449, X.21, RS-485, RS422, EIA-530, 

      EIA-530A

(2). SYNCH and ASYNCH testing

(3).  DTE and DCE emulation

(4).  Bit code testing

(5).  Pattern slip testing

(6).  Signal loss alarm

(7).  Line signal frequency testing

(8).  Loop delay testing

(9).  Automatic protection switching time testing(APS)

(10). G.821, M2100 service-interrupted error testing


Applications for Co-directional 64Kbit/s

(1). Service-interrupted error testing

(2). Bit code testing

(3). Pattern slip testing

(4). Signal loss, AIS alarm

(5). Line signal frequency testing

(6). Loop delay testing

(7). Automatic protection switching time testing(APS)

(8). G.821, M.2100 error performance testing

 


E1/2M Technical Specifications

(1). Signal input rate: 2048Kbit/s ± 50ppm (G.703 requirement±100ppm)

(2). Signal code: HDB3, AMI.

(3). Input jitter tolerance: up to G.823

SAT-1CS-1.jpg

                               Fig. Input Jitter Tolerance


(4). Input Impedance

      Unbalance terminating: 75Ω;  balance terminating: 120Ω

(5). Signal structure

       a. Unframed structure

       b. Framed structure: PCM30, PCM31, PCM30CRC, PCM31CRC, 

            complied with G.704

(6).  Testing pattern: 26-1, 29-1, 211-1, 215-1, 220-1, 223-1, and artificial code

(7).  Error code insertion: Bit Error, Framed Error, Pattern Slip; None, Single, 

       Ratio 10-1~10-7.

(8).  Alarm insertion: No Signal, Frame Loss, AIS, Patten Loss

(9).  Clock offset: ±999ppm

(10). Jitter test: ITU-T G.823, O.172, O.171

(11). Loop delay test: accuracy ±1μs

(12). APS test: accuracy ±1μs

(13). Plus test: ITU-T G.703

(14). Audio frequency test:

Insert single audio frequency signal

Freq. range: 200Hz~3400Hz, step:10Hz

Level range: -60dBm~+3dBm

Test single audio frequency signal

Freq. range: 200Hz~3400Hz, accuracy: ±1Hz

Level range: -60.00dBm~+3.14dBm
  -60.00dBm~-21.00dBm, accuracy: ±2.5dBm
  -20.00dBm~+3.14dBm, accuracy: ±0.25dBm

 

Datacom Technical Specifications

(1). Interface type: V.24/V.28/RS232, V.35, V.36/RS-449, X.21, RS-485, RS422, 

      EIA-530,EIA-530A

(2). Generator

        a. SYNCH mode

            Clock source: internal and picking-up clock

             Phase relation between clock and data: co-direction or reverse direction.

             Rate: 1.2, 2.4, 4.8, 9.6, 14.4, 19.2, 38.4, 48, 56(Kbps), N×64Kbps (N=1~32)

             Error: ±15ppm (ppm: parts per million)

         b. ASYNCH mode

              Rate (bps): 50, 75, 110, 150, 200, 300, 600, 1200, 2400, 3600, 4800, 7200, 

                                 9600,14.4K, 19.2K, 38.4K, 57.6K

               Data structure: Word Length: 5, 6, 7, 8(bits)   Stop Bit: 1, 2(bits)

               Odd-even detection: Odd, Even, 1, 0, None.

          c.  Error code insertion: None, Single, or Ratio 10-1~10-7.

(3). Receiver

          a. SYNCH mode

               Clock source: internal and picking up clock

               Phase relation between receive clock and receive data: Co-direction or 

               reverse direction.

               Clock Rate: 2048Kbps maximum

           b.  ASYNCH mode

                The rate and data structure are as same as the generator.

(4). Testing pattern: 26-1, 29-1, 211-1, 215-1, 220-1, 223-1, and artificial code


Co-directional 64Kbit/s Technical Specifications

(1). Signal input rate: 64Kbit/s ± 50ppm(G.703 requirement ±100ppm)

(2). Input impedance: balance 120Ω, up to G.703

(3). Input jitter tolerance: up to G.823.

(4). Impedance of output interface: balance 120Ω, up to G.703

(5). Testing pattern: 26-1, 29-1, 211-1, 215-1, 220-1, 223-1, and artificial code

(6). Error code insertion: Bit Error, Pattern Slip, None, Single, Ratio 10-1~10-7.

(7). Alarm insertion: No Signal, AIS, Patter Loss


General Specifications

Power Adapter

Input: AC220V 50Hz, Output: DC 9V 1.2A



Battery Capacity


4000mAh, 6V nickel-hydrogen   rechargeable battery,

Working time: 8 hours

Charging: 8 hours at power-off state,  

and 12 hours at power-on state


Dimension

L×W×H: 220×162×48 (mm)

Weight

950g

Operation Temperature

-10~+50℃

Storage Temperature

-30~+70℃

Humidity

5%~90%, non-condensing

 

 